HLP-80H-30
Request a Backorder
Submit your request and we will confirm lead time.
Submit your request and we will confirm lead time.
AC Input Voltage Range
90-305VAC 127-431VDC
AC Inrush Current (max.)
COLD START 70A(twidth=525μs measured at 50% Ipeak) at 230VAC
Over Current Protection
95 ~ 108%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Short Circuit
Hiccup mode, recovers automatically after fault condition is removed
Over-Voltage Protection
14 - 17V | 18 - 24V | 23 - 30V | 35 - 43V | 41 - 49V | 48 - 58V | 54 - 63V | 59 -68V |
Protection type : Shut down o/p voltage, re-power on to recover
Over Temperature Protection
Shut down o/p voltage, re-power on to recover
Withstand Voltage
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
Working Temperature
-40 ~ +70℃(Refer to "Derating Curve")
Safety Standards
UL8750, CSA C22.2 No. 250.0-08 (except for 48V, 54V), BS EN/EN61347-1, BS EN/EN61347-2-13, EAC TP TC 004 approved ; Design refer to UL60950-1
Dimension (LxWxH)
167x53x29.5mm
Your payment information is securely processed through encrypted and PCI-compliant payment systems. We do not store, collect, or have access to your credit card details. All transactions are handled by trusted payment providers to ensure your personal and financial information remains safe and protected at all times.